Exclusive design with double transversal wires for outstanding working-load
Exclusive patented solution for safety edges
Complete range of screw-less accessories
Accessories for direction changes made directly on site
Electrical, telephone and data installations must be easy to install, safe to use and flexible enough to ensure that changes are easy to make.
The design of the visible parts must also set the right tone in the office.
OptiLine 45 direct clic-in installation system provide integrated installation solutions for ceilings, walls, floors and desks.
Together with Altira wiring devices, solutions are created that fulfil the most stringent demands for function, design, convenience and safety.
You might recognize the installation friendly solutions and the high quality and yet, OptiLine 50 is a completely new installation system. Other news: thewhole system is available in halogen-free material and the brand is Schneider Electric.
OptiLine 70 universal installation system provide integrated installation solutions for ceilings, walls and desks.
Together with Altira wiring devices, solutions are created that fulfill the most stringent demands for function, design, convenience and safety.
The new OptiLine mini-trunking system is based on more than 40 years’ experience of developing trunking for electrical installations. The aim was to develop an attractive, functional trunking to meet many different needs, often for small installations.
The trunking would also need to be easy to install and extend, to provide greater electrical safety and be more tamper-resistant that any previous trunking. In addition to all this it would have to be attractive to look at.
Circuit Breakers\ACB
LV power circuit breakers and switch-disconnectors.
Catalogue numbers: spare parts.
Schneider Electric has forged a solid reputation in terms of quality and innovation, continuously integrating the latest technology in all its circuit breakers. Reliability, flexibility and simplicity have always been the top priority. Schneider Electric offers the widest range of products available on the market with frame sizes, accessories and performance
characteristics meeting the requirements of all types of applications.
Masterpact NW 800-6300 A.
The Egaflex PVCu conduit range is a corrugated flexible system which can be used for the connection of vibrating equipment or to provide tight bends for interconnecting conduits. The range can be surface mounted or cast-in concrete and can also be used it standard conduit fittings.
Circuit Breakers\MCB
Modular circuit-breakers up to 63A
North american standards UL,CSA and IEC miniature circuit breaker up to 63A.
High performance circuit-breakser up to 125A
High performance circuit-breakser up to 125A
High performance circuit-breakser up to 160A.
Circuit Breakers\MCCB
Circuit protection and control devices 0.5 to 6300 A
Circuit protection and control devices 0.5 to 6300 A
The new Compact NS line achieves a significant technical advance in the evolution of molded case circuit breakers. These circuit breakers use an entirely new technology in current interruption. Short-circuit protection is enhanced by a unique double rotating break (roto-active breaking system) which brings an exceptional current limitation and outstanding endurance on repetitive short-circuit interruptions..
Circuit protection and control devices 0.5 to 6300 A
With only three sizes of circuit breakers, the EasyPact systems is the simple and universal solution to fit all needs in terms of low voltage protection. It is designed as an alternative for those applications not requiring the high level of characteristics and flexibility provided by the Compact NS range. EasyPact can be used in individual enclosures or as a main in sub-distribution panels.
The original Masterpact has set a new standard for power circuit breakers around the world.
Motor Protection & Starters\Motor protection circuit breakers
The C60LMA circuit breakers are designed to protect motor supply circuits (cables and starters) against short-circuit currents.
As they are equipped only with magnetic trip units, they must be combined with suitable thermal protection.
The Compact NS80H-MA circuit breaker: provides high performance protection against short circuitsis suitable for isolation as defined by IEC 60947-2 standard (disconnector function). For a complete protection of the motor and its starter, the Compact NS80H-MA must be combined with a relay for overload protection. The starter can be of either direct on-line (reversing or not) or "star-delta" type.
NG125LMA circuit breakers are circuit breakers which combine the following functions: circuit protection against short-circuit currents, circuit protection against overload currents, suitability for isolation in the industrial sector to IEC/EN 60947-2, tripping upon fault is indicated by a red mechanical state indicator light on the front face of the circuit breaker.
They protect single-phase or three-phase motors with manual local control.
This protection includes: isolation manual or remote control, short-circuit protection (magnetic),overload protection (thermal
Motor starters
Ready-to-use component combinations, designed to work together in perfect harmony.
Safe operation and level of coordination guaranteed by a major manufacturer.
TeSys motor starters from Schneider Electric offer a wide range of solutions to meet your motor control and protection needs. This data bulletin contains information on applying TeSys motor starters in the United States and Canada.
Motor starters
Ready-to-use component combinations, designed to work together in perfect harmony.
Safe operation and level of coordination guaranteed by a major manufacturer.
Operating Mechanisms, Disconnect Switches, and Door-Closing Mechanisms
Residual Current Breakers with Overload Protection RCBOs
The DPNa Vigi residual current device provides complete protection of final circuits (overcurrents and insulation faults): protection of people against electric shocks by direct contacts (10 and 30 mA), protection of people against electric shocks by indirect contacts (300 mA), protection of installations from fire hazards (300 mA).
Residual Current Devices RCDs
Residual current circuit breakers ensure: the control and isolation of electrical circuits the protection of persons against direct and indirect contacts the protection of installations against insulation faults.
They are conform to both the residual current device standard IEC 61008 and to switch standards IEC 60947-1 and IEC 60947-3.
Residual current circuit breakers are used in the housing, tertiary and industrial sectors.
Residual Devices RCD blocks
Incoming protection and switching.
They are used with C60 1P, 2P, 3P and 4P circuit breakers to provide: protection for users against indirect contacts
additional protection for users against direct contacts (10 mA and 30 mA) protection for electrical installations against insulation faults (fire hazard, etc.).Basic C60 circuit breakers retain their characteristics.
The Vigi NG125 residual current release is electromechanical and operates without an auxiliary source of supply. Its scope of application is therefore extensive. It completes the NG125 circuit breakers to provide: protection of persons against indirect contact
protection of electrical installations against insulation faults.
Change over & Transfer Switches
To ensure a continuous supply of electrical power, certain installations are connected to two sources:b a normal source N,
b a replacement source R used to supply the installation when thenormal source is unavailable.
Switch Disconnectors
Industrial switchboards and automatic ,control panels
Current ratings: up to 400 A Schneider Electric switch-disconnectors: Interpact INS/INV.
Two circuit breakers offer total discrimination when the corresponding box in the discrimination table is shaded or contains the letter T.
When discrimination is partial for the combination, the corresponding box indicates the maximum value of the fault current for which discrimination is provided. For fault currents above this value, the two circuit breakers trip simultaneously.
The switch-disconnectors with I-NA release combine the following functions: control (opening and closing circuits on load) isolation.
They are designed for switchboard incoming ends or enclosures in the tertiary sector and in industry, with the possibility of remote tripping using a coil.
Switch Fuse
Fusegear range from 32 to 800 A.
Plugs & Sockets
PK Plugs and sockets
Low voltage 90° wander plugs
Industrial Plug & Socket
Industrial Plugs and Sockets The PK offer is part of a complete range of high-performance industrial plugs and sockets.
Circuit Breakers\MCCB
Consumer Units
Electrical distribution weatherproof plastic mini enclosure up to 63 A for tertiary, small
contractors’ and industrial buildings. Indoor and outdoor use.
The Micro Pragma is a multi-function enclosure.
It is used indoors, in housing and the commercial building sector, for new and renovated installations.
Mini Pragma
Surface mounting enclosures
Mini Pragma.
The range consists of enclosures with a width of 13, 18 or 24 modules of 1 to 6 rows and interfaces of 1 to 3 rows. The entire range can be associated horizontally or vertically.
Main & Sub Distribution Board
Low voltage equipment for high dependability
Intelligent Power & Motor Control Centre for continuous and critical processes.
Low voltage equipment for high dependability
Simple functional systems, for safe and upgradeable LV switchboards, up to 630 A
Multi Purpose Boxes
Prisma Plus and Spacial SF, more than the sum of their parts.
Discover the new generation of Spacial SF suitable metal enclosures and Spacial SM compact enclosures
Incoming protection and switching.
Universal Enclosures.
Surge & Over voltage arresters
Voltage surges and their protection devices
Analogue telephone line protection: the PRC surge arrester wired in series to the
private installation input protects the telephones, the PABX, the modems
(including ADSL), etc.
Withdrawable Quick PRD surge arresters allow damaged cartridges to be replaced quickly.
They offer remote reporting of the "cartridge must be changed" message.
PRD-DC surge arresters
Withdrawable surge arresters type 2 for direct current.
Voltage surges and their protection devices
Contactors & Relays
Contactors can be used to control:
heating, ventilation, roller blinds, sanitary hot water, mechanical ventilation systems, etc.
load-shedding of non-priority circuits.
Manually-operated contactors let you override the (ON/ OFF) control of the load.
Please provide the picture and info
Please provide the pdf
files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
Please provide the pdf files
TeSyS T
Motor Management System
Please provide the pdf files
Monitoring Relay & Indicating Lights
Merten System M / M-Smart / M-Arc / M-Star / M-Plan / M-Elegance
Merten System M / M-Smart / M-Arc / M-Star / M-Plan / M-Elegance
Saving energy conveniently and reliably
Movement and presence detector
Basic, Medium, Advanced
Indication switchgear
V indicator light
Please provide the pdf files
Commend & Control\Monitoring Relay & Indicating Lights\Flush mounted movement and presence detector
Flush mounted movement and presence detector - CEE 60 PIR
Merten ARGUS surface-mounted movement detectors. Not only does it provides adequate lighting in areas a good distance from the light switch: it also puts uninvited guests into the spotlight - whether they want to be or not
Commend & Control\Switches & Isolators
Modular switch-disconnectors/isolators - I - Miniature switch disconnector
Commend & Control\Twilight Switches
IC twilight switches automatically control lighting, roller blinds... according to light intensity and/or the time of the day.
They measure light intensity using photo cells (except IC Astro) that can be installed on a door ("spy hole" cell) or outside a building (wall-mounted cell).
Protection\Fuse Holder
Fuse carriers, fuse disconnectors - TeSys DF, LS1/GK1 Fuse carriers from 0.5 to 125 A, up to 690 V